1 - 100 HP, O. E. M. UNITS, Drive Panel Systems |
KUKSONS
|
|
|
|
QUALITY AND RELIABILITY WITH TECHNICAL PERFECTION |
|
Single
Quadrant Drives : |
| RATING
VOLTAGE : 415 v. AC 3ph input : 400 v. DC armature 415 v. AC 2ph input : 360 v. DC armature 230 v. AC 1ph input : 180 v. DC armature |
| STANDARD
FEATURES Adjustable soft start. Adjustable current limit. Fuse protection. Stability Potentiometers. RC filter for voltage spike protection. Adjustable minimum speed settings. Meter outputs. Tacho / arm feedback field settable PANEL FEATURES Meters for armature current, armature Voltage and / or speed Isolation contractors fuses and switches Control section isolated from power section Programmable logic controllers Push buttons and indicating lamps Reversing contractors ( optional ) Process instrumentation etc. |
QUALITY
AND RELIABILITY Drives have gained the trust of O. E. M And End user customer due to their quality and Reliability to ensure this only the best components Are used. Assembly work is carefully monitored And every unit/ panel is 100% tested before dispatch. O. E. M SUPPORT Provides full support to O. E. M. Panel and Machine builders to ensure that you get Exactly what you need. We provide comprehensive application engineering support To Our O. E. M. customers. |
| SPECIFICATION
& FEATURES : SINGLE QUADRANT DC DRIVES |
||||||||
| MODELS | KUK-01 | KUK- 02 | KUK-03 | KUK-05 | KUK-07 | KUK-10 | KUK-24(PWM) | |
| POWER | HP / KW | 1 / 0.75 | 2 / 1.5 | 3 / 2.2 | 5 / 3.7 | 7.5 / 5 | 10 / 7.5 | 0.25 / 0.2 |
| WEIGHT | Kg. | 0.3 | 0.5 | 1 | 3 | 7 | 7 | 2 |
| SIZE (mm) | HXWXD |
220X185x60 |
220X210X90 |
220X210X90 |
210X180X130 |
310X260X170 |
310X260X170 |
145X285X110 |
| INDICATION | Enable | Enable/Phase Fail | Enable | |||||
| Regulation | Taco Fail/Start | Regulation | ||||||
| Curr. limit | Over Temp | Curr. limit | ||||||
| FUSE PROTECTION |
YES | YES | YES | EXT | EXT | EXT | YES | |
| CURRENT (MAX) |
AMP | 5 | 10 | 15 | 25 | 38 | 50 | 6 |
| A.C. POWER SOURCE | 230 V, 1 PH | N. A | 220 VAC | |||||
| N. A | 415 V, 3 Ph | 1 Ph | ||||||
| D.C | ARMATURE | 180 V.D.C | N.A | 0 - 48 V | ||||
| OUTPUTS | FIELD | 200 VDC / 360 VDC | N.A | |||||
| SPEED CONTROL |
ARMATURE | 20 : 1 (3%) | ||||||
| RANGE
& ACCURANSY |
TACHO | 50 : 1 (1%) | ||||||
| STANDARD FEATURES | SOFTSTART / FIELD FAILURE PROTECTION / IR COMPENSATION | |||||||
| CURRENT LIMIT (50-125%) Sustained Overload Trip | ||||||||
| Armature & Taco Feedback / Speed Limit Minimum & Maximum (60%-100%) | ||||||||
| OPTIONAL FEATURES | Tacho Failure Detect & Trip / Current trip Indication / Opto Isolation / softstop / Braking | |||||||
| EXTERNAL
CONTROL ( SET - POINT ) INPUT |
POTENTIOMETER ( standard ) | |||||||
| Or 0 - 10 VDC SIGNAL / 4 - 20 mA ( optional ) | ||||||||
| SPEED SIGNAL OUTPUT | 0-1mA (standard) 4-20mA (optional) / (meter/Tacho Repeater) | |||||||
| ENCLOSURE | Wall mounting type, semi closed | |||||||
|
To Order specify :
KUK - A B C |